80100, 26230
G1/4, G1/2
3/2, 4/2, 5/2
3000 l/min
Technical data
Operating medium:
Solenoid valve for filtered, lubricated1) or non-lubricated air
Action:
Solenoid operated indirectly controlled
Flow direction:
Fixed
Mounting position:
Optional
Nominal size:
6 and 12 mm
Port size:
G 1/4, G 1/2
Electrical connection:
Connector interface to DIN 43650 form A and B
Operating pressure:
1 to 10 bar
Temperature range:
-10* to +50 °C
* With minus temperatures use conditioned dry air. If installed in the open protect all connections against the penetration of moisture!
Material:
Housing: Aluminium
Pilot flange: Plastic (PBT)
Seal: NBR (Perbunan)