VP40
G1/8, G1/4, G3/8
£ 20 bar
1900 l/min
Technical Data
Medium:
Filtered air, lubricated or unlubricated,
Filter 40 μm
Operation:
Proportional solenoid
Port Size:
G 1/8 - G 3/8, 1/8 NPT - 3/8 NPT
Female thread
Flow direction:
Fixed
Operating pressure p1:
20 bar max.
Pressure setting p2:
0 to 20 bar
Ambient temperature:
-10 to +40 °C
Hysteresis: *
< 3 % (lN max, p2 max)
Repeatability: *
< 1 % (p2 max)
Linearity: *
See characteristic curve
Response sensitivity: *
< 1 % (lN max, p2 max)
Degree of protection:
IP 65 with connector
Mounting:
Any, preferably vertical
Material:
Body aluminium alloy
Seals NBR (Perbunan)